- Voltage alarm function (over voltage alarm threshold Backlight and voltage flashing to alarm).
---------------------------
Note:
Before you use the 50A/100A/75mv shunt please set the range of the meter to 50A or 100A(the default setting is 100A)
Step1: Long press the key until the power area display “Curr” then release the key
Step2: At this moment the current area display “100A” short press the key to switch between“100A”and “50A” to prompt the range of the external shunt is 100A/75mV or 50A/75mV
Step3: Long press the key to exit the setting state or after no operation within 3 seconds it will store automatically and exit the setting state.
Function 1. Electrical parameter measurement function (voltage current active power energy)
2. Voltage alarm function (over voltage alarm threshold backlight and voltage flashing to alarm).
3. The reset function of energy key.
4. Store data when power off.
5. Large-screen LCD (display voltage current active power energy at the same time)
6. Backlight function.
Appearance and Key function
I. Display Interface
Display interface is large-screen LCD it can display voltage current power energy parameters at the same time.
II. Display format
Power: test range: 0~10kW within 1KW the display format is 0.0~999.9W;
1KW and above the display format is 1000~9999W.
Energy: test range: 0~9999kWh Within 10KWh the display format is 0~9999Wh;
10kWh and above the display format is 10~9999kWh.
Voltage: test range: 6.5~100V Display format: 6.50~99.99V
Current: test range: 0~100A Display format: 0.00~99.99
III. Key
Backlight control Short press the key to turn on or off the backlight the backlight has memory function it can store the on or off state when power off.
Reset energy Step1: Long press the key until the power display area display “CLr” then release the key.
Step2: At this moment the energy is flashing to prompt this is the energy reset state if short press the key again then the energy value is cleared and exit the reset flashing state.
Step 3: If there is no operation within 5 seconds it means the energy value is not cleared and will exit the reset state.
Set voltage alarm threshold Step1: Long press the key until the power display area display “SET” then release the key. Step2: After enter this state the voltage area display the current high voltage alarm value the current area display the current low voltage alarm value and the last digit begin to flash then you can short press to plus 1 when there is no operation over 3 seconds it will switch the digit position automatically from the high voltage alarm value to the low voltage alarm value there are total six digits the range of the voltage alarm threshold is 6.5~99.9V; Step3: After finish the setting long press the key until the screen display “PASS” that means you set successfully and will exit the setting state automatically.
มาแล้ว มิเตอร์ วัดไฟ DC PZEM 051 / PZEM 031 DC 0-100A 4 in 1 กระแสตรง 6.5-100V DC Watt meter Volt Current Watt Energy [ MT ]
สั่งซื้อเลย มิเตอร์ วัดไฟ DC PZEM 051 / PZEM 031 DC 0-100A 4 in 1 กระแสตรง 6.5-100V DC Watt meter Volt Current Watt Energy [ MT ]
จัดหนักนาทีนี้ มิเตอร์ วัดไฟ DC PZEM 051 / PZEM 031 DC 0-100A 4 in 1 กระแสตรง 6.5-100V DC Watt meter Volt Current Watt Energy [ MT ]
การรีวิว มิเตอร์ วัดไฟ DC PZEM 051 / PZEM 031 DC 0-100A 4 in 1 กระแสตรง 6.5-100V DC Watt meter Volt Current Watt Energy [ MT ]
ลดพิเศษมากสุด มิเตอร์ วัดไฟ DC PZEM 051 / PZEM 031 DC 0-100A 4 in 1 กระแสตรง 6.5-100V DC Watt meter Volt Current Watt Energy [ MT ]